Back to the product
Certification

Certified, tested, and on the record.

The TH-100 carries an EU-Type Examination Certificate under Regulation (EU) 2016/425, issued by ANCCP Certification Agency against EN 341 : 2011. Both the certificate and the test report behind it are reproduced here in full.

Regulation (EU) 2016/425
EN 341 : 2011
Annex V — Module B
Valid to 23 / 07 / 2030
Document one

EU-Type Examination Certificate

Certificato di Esame UE del Tipo

Certificate no.
PPE-3039-23731-Cert
Regulation
(EU) 2016/425 — Personal Protective Equipment
Type of PPE
High-rise escape descender
Model
TH-100
Applicant
LPH CO LTD. — Escape One, The Descender
Address
Ahmedabad, Gujarat, India
Harmonized standard
EN 341 : 2011
Conformity procedure
Annex V (Module B)
Issued by
ANCCP Certification Agency S.r.l., Livorno, Italy
First issue
24 / 07 / 2025
Current issue
24 / 07 / 2025
Expiration
23 / 07 / 2030

The applicant is authorized to affix the CE marking to the approved product under Art. 17. To place the PPE on the market the applicant must also acquire conformity under Annex VII (Module C2) or Annex VIII (Module D) issued by a Notified Body.

EU-Type Examination Certificate PPE-3039-23731-Cert, issued by ANCCP Certification Agency to LPH CO LTD. for the ESCAPE ONE TH-100 high-rise escape descender under Regulation (EU) 2016/425.
PPE-3039-23731-CertView full size
Document two

Test Report PPE 23731 RP 001 — Rev. 00

The certificate rests on this report: 5 pages of bench testing carried out by ANCCP against EN 341 : 2011, sample by sample. Every figure below is quoted from it.

Type of PPE
Descender device for rescue
Model
TH-100
Date of issue
09 / 06 / 2025
Samples received
15 / 05 / 2025
Date of testing
16 / 05 – 09 / 06 / 2025
Assessor
Giuseppe Gazzerro, ANCCP CA
Dry, 20 °C
0.58 – 1.23 m/s
30 kg to 125 kg
Wet
0.62 – 1.18 m/s
immersed 60 min
Wet and cold
0.64 – 1.15 m/s
−4 °C for 4 h
Static strength
12 kN / 3 min
and 6 kN / 3 min

Results recorded

  • 4.1.1Minimum rated load30 kgPass
  • 4.1.2Maximum rated load100 kgPass
  • 4.2.1Design, materials and constructionConnectors to EN 362, Class BPass
  • 4.2.2LinesSteel wire ropePass
  • 4.2.2.1Wire rope linesSteel wire ropePass
  • 4.2.2.4Line integrityHeld the test force at 100 kgPass
  • 4.3Dynamic strengthNo release, no breaking or tearingPass
  • 4.4.1Classes A, B and CClass C / Type 1 — 0.58–1.23 m/sPass
  • 4.5Descent energy0.97 m/s at 100 kg over 100 mPass
  • 4.6Static strength12 kN, then 6 kN, 3 min eachPass
  • 4.7Corrosion resistanceNo corrosion after 2 × 24 hPass

Full scope of testing

The clauses the report lists as tested. Those without a result above are ones it records no separate outcome for.

·4.1.1 · Minimum rated load
·4.1.2 · Maximum rated load
·4.2.1 · Design, materials and construction
·4.2.2 · Lines
·4.2.2.1 · Wire rope lines
·4.2.2.2 · Textile rope lines
·4.2.2.3 · Webbing lines
·4.2.2.4 · Line integrity
·4.2.2.5 · Terminations, end stops
·4.3 · Dynamic strength
·4.4.1 · Classes A, B and C
·4.5 · Descent energy
·4.6 · Static strength
·4.7 · Corrosion resistance
·4.8.1 · Operating force
·4.8.2 · Holding force

The report itself

All 5 pages, exactly as issued.

Test report PPE 23731 RP 001, page 1 of 5
Page 1 of 5
Test report PPE 23731 RP 001, page 2 of 5
Page 2 of 5
Test report PPE 23731 RP 001, page 3 of 5
Page 3 of 5
Test report PPE 23731 RP 001, page 4 of 5
Page 4 of 5
Test report PPE 23731 RP 001, page 5 of 5
Page 5 of 5